Lipids are crucial elements of the mobilephone membrane proven to play many dynamic roles in mediating and controlling a wide range of mobile actions together with membrane constitution and association, metabolic and gene law, protein constitution and serve as, strength creation and signalling pathways.

Additional info for Agilent 89410A Analyzer (installation and verification)

Example text

The values measured determine insertion loss. 1 2 2-24 Option AY7 only Agilent 89410A Verifying Specifications To set up the input trigger test To set up the input trigger test Performance Test and Operation Verification This test verifies that the Agilent 89410A meets its trigger specification for input channel trigger. In this test, a signal is connected to the Agilent 89410A. Trigger level and slope are then verified by reading the signal level and slope at 0 seconds in the time record. 1 2 Option AY7 only 2-25 Verifying Specifications To set up the external trigger test Agilent 89410A To set up the external trigger test Performance Test and Operation Verification This test verifies that the Agilent 89410A meets its trigger specification for external trigger.

234 kHz in the 50 ohm and 1 Mohm impedance paths. The following lists the attenuator settings for each amplitude: Amplitude −30 dBm −18 dBm −6 dBm +6 dBm +18 dBm 10 dB Step Attenuator 50 dB 30 dB 20 dB 10 dB 0 dB 1 dB Step Attenuator 0 dB 8 dB 6 dB 4 dB 2 dB 1 2 2-16 Agilent 89410A Verifying Specifications To set up the amplitude accuracy test 3 4 Option AY7 only 5 Option AY7 only 2-17 Verifying Specifications To set up the amplitude accuracy test 6 7 8 2-18 Agilent 89410A Agilent 89410A 9 Verifying Specifications To set up the amplitude accuracy test Option AY7 only 10 Option AY7 only 2-19 Verifying Specifications To set up the amplitude linearity test Agilent 89410A To set up the amplitude linearity test Performance Test only This test verifies that the Agilent 89410A meets its amplitude linearity specification.

The directions on the display briefly tell you how to connect test equipment. For detailed illustrations of equipment setup, see the setup illustrations starting on page 2-14. If you want to pause the program and return the Agilent 89410A DC-10 MHz Vector Signal Analyzer to front panel control, press [ BASIC ]. To continue the program, press [ Display ] [ BASIC display format ] [ lower ] [ BASIC ] [ continue ]. If you changed any instrument setup states, press [ RESTART TEST ] to ensure accurate measurement results.

Download PDF sample

Agilent 89410A Analyzer (installation and verification)


by Thomas
4.3

Rated 4.80 of 5 – based on 14 votes